SmartFlow Technology



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

Parts Identification

larger image
Expandable Modular System
Only purchase the capacity of your current requirement.




Features · Details

Features
    Integrated Control Panel Energy Management



    Based on inputs from pressure sensor and machine controls determines the fan speed to provide required extraction requirement.
    Dust collection on demand = 25%-60% savings in energy costs.

    Direct Drive Fans



    Eliminates 4-6% in belt energy loss.
    Eliminates belt maintenance costs.

    Pressure Sensor



    Feeds readings to VFD and control panel to fan RPM.

    Automatic Blast Gates



    Automatically shuts off ports not in use, reducing the energy consumption of system.

    Return Air System
    Saves on heating and cooling costs by returning air back to workspace.

    Variable Frequency Drive



    Increases or decreases fan speed to match the online requirement.
    Ramps voltage level during start up to reduce electrical costs and wear and tear on system components.




Details
    How it works
    Configured exactly the same as the Non-Integrated System except a main PLC controller determines the correct fan speed through control logic that takes into account the number and identity of machines in operation, the pressure in the main line and the pipe system design. With this integrated system, the maximum energy savings are obtained in comparison to the above methods.

    Main Components
    Automatic Blast Gates with a control circuit link to the machine controls, Direct Driven Fan driven by a Variable Frequency Drive, Pressure Sensor with PID Feedback Loop to VFD, Engineered Quick fit Pipe System

    Benefits of Fan Zoning versus traditional system
    Reduce Energy Costs as much as 60%.
    Minimize Filter and Sound Emissions.
    Decrease make up air system requirements thus saving on electrical costs.

    Benefits of Integrated versus Non-Integrated Energy Management System
    As much as 50% more energy savings
    Ability to recover production usage data
    "Dust Collection on Demand" - Reduce the size of the fan and dust collector.




 DOWNLOADS 

 width= Expectations and Results